Proviron Deicing Technology

GB | NL
About us | Deicers | Airport Deicers | Road deicers
General | Specifications | Technical data | Application guidelines | Equipment | FAQ | Certifications
General | Specifications | Technical data | Application guidelines | Storage & Handling | Certifications
General | Specifications | Technical data | Environment | Application guidelines | Storage & Handling | FAQ
General | Specifications | Technical data | Environment | Application guidelines | Storage & Handling | FAQ
Biodiesel at Proviron
subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link | subglobal7 link
subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link | subglobal8 link

Cryotech CF7® - Environment

Environmental Impact

Tests with CF7 show it readily biodegrades at low temperatures and has a relatively low oxygen demand (BOD) when compared to glycol-based deicers. Toxicity tests rate CF7 “relatively harmless” to aquatic life, the most favorable classification used by the environmental community. And the fluid does not contain nitrogen. Therefore, CF7 is considered much safer for the environment than either glycol or urea. As suggested by federal agencies, the following general summary of environmental and hazard information is provided. More detail is available in the MSDS. Complete test report documentation is available upon request.

Biodegradability

The chemical oxygen demand (COD) of CF7 was determined using EPA Method 410.1

  • COD (TOD) = 0.30 gm O2/gm

The biological oxygen demand (BOD) of CF7 was determined using the EPA approved dilution method (Hach).

  • BOD20 @ 2°C = 0.30 gm O2/gm
  • BOD20 @ 20°C = 0.30 gm O2/gm
  • BOD5 @ 20°C = 0.14 gm O2/gm

Hazard Information

Hazardous Waste & Shipping

The RCRA regulations define hazardous waste in two ways: a listed hazardous waste or a characteristic hazardous waste. CF7 is not a listed hazardous waste. A waste may be considered hazardous if it exhibits any one of four characteristics - Corrosivity, toxicity, ignitability, or reactivity. A waste is corrosive under RCRA if it has a pH less than or equal to 2.0 or greater than or equal to 12.5. CF7 is not RCRA corrosive, toxic, ignitable or reactive; therefore, it is not a characteristic hazardous waste.

No Hazardous Components

CF7 contains no hazardous components as described by SARA Title III, Section 302. Nor is CF7 designated as a hazardous chemical by the U.S. Department of Transportation. CF7 does not contain nitrates.

Spill Handling Procedures

CF7 is not expected to present environmental problems. If product should spill, it should be absorbed and the resulting waste disposed of in a sanitary landfill unless state or local regulations prohibit such disposal.

Container and Product Disposal

Based on information available to Cryotech Deicing Technology, CF7 is neither listed as a hazardous waste, nor does it exhibit any of the characteristics that would cause it to be classified or disposed of as a RCRA hazardous waste. Empty containers and product unsuitable for normal deicing operations may be disposed of in a sanitary landfill unless state or local regulations prohibit such disposal.

Home | About Us | Contact Us | ©2007 Proviron Deicing Technology

Proviron

G. gilliotstraat 60 - 2620 Hemiksem - Belgium - Tel +32 3 870 88 20 - Fax +32 3 877 23 33